rapid diagnostic test solutions at Innovadyne Technologies
The liquid handling requirements for rapid diagnostic test production are exacting and, with the advancement of molecular diagnostic technologies, increasingly complex. New diagnostic kit technologies may require the precise deposition of multiple reagents, difficult-to-dispense reagents (such as particulates or beads) and/or costly genetic samples, sometimes in complex dispense patterns.
Additionally, system downtime and difficult-to-reproduce dispensing results are anathema to the exacting world of diagnostic test kit production. Traditional (flow-through) low-volume liquid handling technologies frequently suffer either from the effects of inline manifolds or valves located in the fluid path. These systems have poor precision and accuracy, poor reliability and require large dead volumes.
Innovadyne’s aspirate and dispense architecture, with a valve-free fluid path, creates a flexible device that is capable of dispensing a wide variety of reagents with much less maintenance than flow-through systems. Innovadyne’s proven fluid path technology isolates the syringes and solenoid valves so that they remain in a pristine system fluid environment (degassed, de-ionized water) and so reagents never come in contact with these parts. Combined with tip washing by means of an integrated wash station, an Innovadyne Nanodrop stage can dispense multiple reagents without cross-contamination and function maintenance-free inside a containment cabinet for long periods of time.
Innovadyne instruments address the following diagnostic kit production needs in different ways:
Conveyor and reel-to-reel dispensing can be performed with a small-footprint Nanodrop MD-8 or MD-16 stage.
Complex slide dispense patterns can be dispensed with any Nanodrop system, onto SBS-footprint slide-holder plates. Dispense patterns and parameters can be controlled with software ranging from a simple GUI to fully programmable .NET based Nanobuilder sequences.
Existing motion control systems can be retrofitted to use an 8-channel or 16-channel Nanodrop fluidics module.
Features (all platforms)
Small footprint 8-tip and 16-tip stages available that cantilever out over reel-to-reel and conveyor systems
Single tip access for rare compounds
Independent channel spotting enables spotting of unique dispense maps
Easy to maintain and clean
Flexible aspirate and dispense settings
User defined syringe speeds and pressure set points
Ability to clean nozzles between runs
Low-dead volumes
Large dynamic volume range: 100 nL-40 uL
96, 384, 1536, 3456 plates (including low-profile and deep well)
User-friendly software
Simple to integrate with drivers available from most integrators
Platforms
Item |
Description |
Plate Positions |
8-Tip Head |
16-Tip Head |
Syringe Channels |
1,4, or 8-Tip Additions to all Wells |
10808 |
Nanodrop 8-channel fluidics only |
- |
- |
- |
8 |
- |
- |
Nanodrop MD-8 stage and fluidics |
- |
Yes |
- |
8 |
- |
10591 |
1 |
Yes |
- |
8 |
Yes |
|
11638 |
2 |
Yes |
- |
8 |
Yes |
|
12056 |
1 or 2 |
- |
Yes |
16 |
Yes |
Software
Item |
Description |
11727 |
|
10591 |
Nanodrop GUI (for Nanodrop only) |
Accessories
Item |
Description |
11193 |
|
|
Wide-bore tip set (200 µm) (all platforms) |
Specifications
Return-To-Spot Accuracy | 0.1 mm |
Aspiration Range, 8-Tip Head | 0.1-500µL |
Dispensing Range (8-Tip Non-Contact) | 0.1-40µL |
Dispensing Precision, 8-Tip Head | CV<10% at 100nL, CV<7% at 200nL, CV<5% at 1µL |
Dispensing Accuracy, 8-Tip Head | ±10% at 100nL, ±7% at 200nL, ±5% at >1 µL |
Dead Volume, 8-Tip head | 1.5µL/channel at 1µL across 384-well plate |
Syringe Capacity | 500, 1000µL |